ITEM.NO. | NOMINAL SIZE | RANGE OF APPLICATION | FILLING PRESSURE (BAR) |
MAX. PERMISSIBLE BACK PRESSURE | EMPTIED PIPEBUBBLE | WEIGHT (KG) | SHACKLES | FILLING VALVE | ||||
MIN. DIAM. (MM) | MAX. DIAM. (MM) | WATER-COLUMN (BAR) | WATER-COLUMN (M) | DIAMETER (MM) | WIDTH (MM) |
LENGHT (MM) |
THREAD M | THREAD SIZE |
||||
529411 | 600-1000 | 600 | 1000 | 1 | 0.7 | 7 | 580 | 910 | 2100 | 18 | 12 x 2 | 2 x R1/2″ |
529412 | 800-1200 | 800 | 1200 | 0.9 | 0.6 | 6 | 780 | 1230 | 2500 | 29 | 12 x 2 | 2 x R1/2″ |
529413 | 1200-1600 | 1200 | 1600 | 0.8 | 0.5 | 5 | 1170 | 1830 | 3200 | 51 | 12 x 3 | 2 x R1/2″ |
529414 | 1600-2000 | 1600 | 2000 | 0.6 | 0.4 | 4 | 1560 | 2450 | 4000 | 86 | 12 x 3 | 2 x R1/2″ |
529491 | 1900-2200 | 1900 | 2200 | 0.5 | 0.3 | 3 | 1850 | 2910 | 4800 | 100 | 12 x 4 | 2 x R1/2″ |
545429 | 2400-2500 | 2400 | 2500 | 0.5 | 0.3 | 3 | 2350 | 3690 | 5600 | 222 | 12 x 6 | 2 x R1/2″ |
545430 | 2600-2700 | 2600 | 2700 | 0.4 | 0.2 | 2 | 2550 | 4000 | 6500 | 288 | 12 x 6 | 2 x R1/2″ |
545431 | 2800-2900 | 2800 | 2900 | 0.3 | 0.1 | 1 | 2740 | 4300 | 7000 | 332 | 12 x 6 | 2 x R1/2″ |
545432 | 3000 | 3000 | 3000 | 0.3 | 0.1 | 1 | 2930 | 4600 | 7500 | 377 | 12 x 6 | 2 x R1/2″ |
Shut-off Bubble cushion-shape PLUGY Sava
Shut-off bubble CUSHIONSHAPE PLUGY Sava
Pillow-shaped shut-off bubbles are used for large pipe dimensions from 600 to 3000 mm where the access to the pipe has a small diameter. Due to the construction and use of flexible materials, the bubble can be folded to a minimum and can be installed through a 600mm renovation shaft. Compressed air supply via Geka coupling and screwed-on fastening eyelets round off the robustness of these cushions.
Equipment / Special feature:
-Fits folded through a 600 mm renovation shaft
-Highly flexible and completely foldable
-Compressed air connection with Geka coupling
-drawbar eyes on both sides
Additional information
nominal size | 1200-1600 mm, 1600-2000 mm, 1900-2200 mm, 2400-2500 mm, 2600-2700 mm, 2800-2900 mm, 3000 mm, 600-1000 mm, 800-1200 mm |
---|